Es99: Controller Manual Pdf !new!
Knowing these codes alone can save a service call.
To exit, wait 15 seconds without pressing any buttons, or hold and UP together. Essential Parameter Chart Parameter Code Description Standard Default Hy Control Differential (Hysteresis) 2.0°C / 4.0°F Prevents rapid cycling of the compressor or heater. LS Minimum Setpoint Limit Min range value Sets the lowest temperature the end-user can select. US Maximum Setpoint Limit Max range value Sets the highest temperature the end-user can select. ot Thermostat Probe Calibration Corrects offset errors introduced by long sensor wires. od Output Delay at Startup Delays output activation upon powering up the unit. AC Anti-Short Cycle Timer Minimum time the output must stay off before restarting. 4. Maintenance and Troubleshooting
The is a vital component found in various electric scooters, e-bikes, and small electric mobility devices. Acting as the brain of the vehicle, the controller manages battery power, motor speed, and user inputs from the throttle and display.
The monitored temperature has exceeded the maximum threshold for longer than the programmed alarm delay. es99 controller manual pdf
This section explains panel cut-out dimensions (typically 92x92mm, 96x96mm, or 48x96mm). It also warns about ventilation, ambient temperature limits, and avoiding electrical noise from inverters or contactors.
Used to enter menus, confirm selections, and cycle through parameters.
If you are looking to download the official print-ready document, you can save this web guide or print it directly via your browser's feature to maintain a hard copy inside your electrical control panel. Knowing these codes alone can save a service call
Set to 0000 to unlock all parameters, or 1111 to lock changes and prevent unauthorized tampering. 6. How to Run Auto-Tuning (AT)
Always disconnect the main power supply before handling physical wiring connections. Terminal layouts can vary slightly by manufacturing year, but the standard ES99 mapping follows a strict geometric layout.
When the ES99 encounters a system fault, it flashes an error code on the LED screen and triggers the auxiliary alarm relay. LS Minimum Setpoint Limit Min range value Sets
The parameters within the ES99 are split into separate tiers to prevent accidental tampering with core operational logic during routine use. Level 1: Operation Menu (Standard Users)
Connect the live wire to and the neutral wire to Terminal 2 .
Before diving into manual operations, technicians must understand the fundamental physical and electrical parameters of the unit. Operating or wiring outside these ratings will permanently damage the microprocessing chip.